Take Photos of
Pole ID (if tagged) // Entire pole // Cables & assets on pole // Crossarms // Any damage
Pole ID
*
If we are NOT replacing Crossarms go to:
If we are NOT replacing the Crossarm
We must give at least one reason
(At the Bottom of this form)
How many Fuses on the Pole
*
PF- 0
PF- 1
PF- 2
PF- 3
PF- 4
PF- 5
PF- 6
PF- 7
PF- 8
PF- 9
PF- 10
How many Fuses on Barge
*
BF- 0
BF- 1
BF- 2
BF- 3
BF- 4
BF- 5
BF- 6
BF- 7
BF- 8
BF- 9
BF- 10
Get the Drawing for LV Poles
If there is 20% plus Deviation go to:
Im not sure about the Crossarms
NETWORK POLE
Single Top Arm
with Pin Insulators
What is the Lower Arm
*
1 way Tee off -OD 4.1
2 way Tee off -OD 1.1A
There is No Lower arm -OD 1.1A
NETWORK POLE
Double
Top Arm
with Pin Insulators
What is the Lower Arm
*
1 way Tee off -OD 4.2
2 way Tee off -OD 2.2
There is No Lower arm -OD 4.2
NETWORK POLE
Double
Top Arm
is Shackled Off
What is the Lower Arm
*
1 way Tee off -OD 4.3
2 way Tee off -OD 5.1
There is no service arm -OD 4.3
NETWORK POLE
Double
Top Arm
has Shackles & Pins
Double Top Arm is Shackle & Pin
*
2 way T off -OD 2.3
SERVICE POLE
Centre Arm
*
Double Arm Through -OD 7.3 L
Double Arm End Term -OD 7.3 K
Single Arm Through -OD 7.3 I
Side Arm
*
Double Arm Through -OD 7.1 D
Double Arm End Term -OD 7.1 C
Single Arm Through -OD 7.1 A
Im not sure about the Crossarms
Review The Crossarm Configuration
*
-OD REVIEW
What Cross Arms are on the pole
Crossarms On the Pole
*
C12- 1000 x 75 x 75 (x1)
C12- 1000 x 75 x 75 (x2)
C12- 1270 x 75 x 75 (x1)
C12- 1270 x 75 x 75 (x2)
C16- 1680 x 75 x 75 (x1)
C16- 1680 x 75 x 75 (x2)
C21- 2100 x 100 x 75 (x1)
C21- 2100 x 100 x 75 (x2)
C16- REVIEW Crossarms
Cable Guards & UV Damage
Install Cable Guards
*
RT- NO
RT- YES
RT- REVIEW
Is there UV damage
*
UV- NO
UV- YES
UV- REVIEW
Select any Additional Info
Notables
*
AI- Krone Switch on Pole
AI- TMP BusStop StopSign Crossing
AI- 3rd Party Assets on the Pole
AI- Trees are in Lines
AI- Clean off Redundant Equipment
AI- Pole is on Lean
AI- Pole is Splitting at Crossarm Bolt
AI- Deviation on Lines
AI- REVIEW Notables
If we are NOT replacing the Crossarm
We must give at least one reason
What is the Reason
*
AI- Crossarm is in Good Condition
AI- Drop Pole
AI- Larch Pole
AI- New Pole
AI- Pole has Cracking at Crossarm
AI- Pole is Behind Fence
AI- Red Zone
AI- Pole is not in use
AI- Pole needs Replacing
AI- Pole has Extension Arm
AI- REVIEW Replacement
Are We Replacing the Cross Arm
Crossarm Replacement
*
RC- NO
RC- YES
RC- REVIEW